• IUC Technologies combines convenience and functionality in it's new closed circuit control system. The SVS-1000 is the only low voltage (30Vdc Max.), two diver, 19" rack mounted, combination video lamp control and video overlay system currently available.
  • The BIRNS Doubly-Safe Chamber Light™, BIRNS Model 4123, combines powerful LED technology with BIRNS exclusive design features—for the ultimate in safety and performance in brilliant 5200K lighting for PVHO applications.
  • The Amron Model 8120-HP High Pressure - 2 Commercial Diver Air Control and Depth Monitoring System is a system consisting of a two commercial diver depth monitoring system with high accuracy precision gauges and two commercial diver air control manifold housed in a highly durable pressure molded fiberglass case.
  • SUBSALVE USA Commercial Lift Bags are capable of being used by a single diver. These heavy-duty lift bags are ideal for use in light salvage, object recovery, construction, and scientific applications.
  • The DPM72 CO2 Carbon Dioxide analyser is a self-contained modular unit housed in a custom 3u x 1/2 rack width case, that can also be panel mounted.
Home :: Air Control Systems :: With Communications :: Amcommand™ I 1-Diver Air Control/Communications

Amcommand™ I 1-Diver Air Control/Communications

Amcommand™ I 1-Diver Air Control/Communications

 Air Control

  • High Pressure Side
    • Two high pressure air supply connections with two color coded, 6ft SCUBA yokes and whips. The whips and yokes remain attached to the lid of the unit during storage or transit.
    • Each input has a color coded shut off valve and an air pressure gauge which allows the tender to change out the air bottles in the system.
    • As an added safety feature, check valves on each input provide protection against back flow of air from a full bottle to the empty in case the tender forgets to close the valve when switching bottles.
    • A high quality Tescom adjustable, non-venting regulator reduces the high pressure air to low pressure air. The pressure reducing regulator input is protected against contamination by a 50 micron filter and a 0-400 PSIG air pressure gauge monitors the output air pressure. A relief valve (factory set at 285 PSIG) limits over pressurization.
  • Low Pressure Side
    • Input check valve permits simple switching to back-up high pressure air in the event of low pressure air failure. Back-up high pressure air supply can simply be turned on. Commercial diver umbilical air connection is an oxygen type fitting, controlled by a quarter turn ball valve which permits unrestricted flow.
Communications
  • The 2810A 1 diver air radio comes complete with a hand-held push-to-talk microphone which cancels top side background noise and provides clear communication to the commercial diver.
  • The communicator has individual volume controls for the commercial diver and tender which provides for individual preferences of volume. Dynamic 22 watt 'voice power' insures clear hardwire communications even under difficult conditions.
  • The radio has AC power with battery back-up power. The system can also be powered from an external 12V source or the 110/220 volt battery charger. A red LED battery condition indicator also functions for external power sources.
Pneumo System
  • The Pneumo System measures the commercial diver's depth by supplying air pressure to the pneumo hose.
  • The heart of the pneumo system is the high precision 6" depth gauge. The depth gauge dial has a glare free face and is clearly marked for fast, accurate readings. Accuracy is .25%, full scale. The air control system has a built-in snubber for reducing pulsating and shock pressure loads to the precision gauges.
  • The Diver Pneumo is a valve regulating type with yellow handle and controls the air supply to the pneumo fathometer system.

Heating Element Option

  • The Amron 8111-H includes an 18 foot heating cable that will allow for diving in air temperatures below 45 degrees. The heating cable is wrapped around the HP input and regulator section located on backside of manifold panel. The standard plug connect 120 VAC heater is located on the front panel for ease of use.
Specifications
  • Commercial Diver Air Control Specifications
    • HP Air Supply Pressure: 500-4500 PSI
    • HP Air Supply w/ DIN: 2 Source Select
    • HP Inlet Valve: 0-5000 PSI Accuracy +/- 1.5% of Full Scale
    • HP Pressure Gauge: Two (2) Check Valves prevent reverse inlet flow
    • HP Check Valve: Two (2) Input Yokes, with 6ft. high pressure hose whips
    • HP Yokes & Whips: 50 Micron In line
    • HP Pressure Reducing Regulator Output: Tescom® High Pressure Regulator
    • HP Pressure Reducing Regulator Max: 0-285 PSI
    • HP Inline Air Filter: Cv =.06
    • LP Relief Valve: 4500 PSI
    • LP Output Fitting: O2, 9/16-18 RH oxygen (B size)
    • LP Inlet Fitting: #6 JIC
  • Hardwire Commercial Diver Communications Specifications
    • Power: 110/220VAC 50/60Hz (automatic) with internal/external battery, 12VDC
    • Battery Life: 50 Hours (approx)
    • Frequency Response: 300Hz - 3kHz
    • Audio Power: 22 watts per channel
  • Pneumo Specifications
    • Pneumo Gauge: 6 Inch Dual Scale 0-250 FSW/76 MSW
    • Pneumo Fitting: 02 (37° JIC optional)
  • Panel Specifications
    • Panel Material: Black polyester powder coated over stainless and aluminum
    • Graphics: Red, white and blue silk-screened
Details
SKU 8111
Quantity in stock No items available
Weight 46.00 lbs
 
Our price: Call For Pricing!
Options
Item:
Quantity Item currently out of stock but available for purchase. Please contact for estimated delivery dates, (855) 482-8324.

Product rating

Sign in to rate

Customer Reviews

There have been no reviews for this product.
Amron 3 Commercial Diver Air Control - High Pressure System
Amron 3 Commercial Diver Air Control - High Pressure System
: *
: *
: *
Type the characters you see in the picture:


*